Electronic Components Datasheet Search |
|
HCTS164DMSR Datasheet(PDF) 8 Page - Intersil Corporation |
|
HCTS164DMSR Datasheet(HTML) 8 Page - Intersil Corporation |
8 / 8 page 8 All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see www.intersil.com Sales Office Headquarters NORTH AMERICA Intersil Corporation 7585 Irvine Center Drive Suite 100 Irvine, CA 92618 TEL: (949) 341-7000 FAX: (949) 341-7123 Intersil Corporation 2401 Palm Bay Rd. Palm Bay, FL 32905 TEL: (321) 724-7000 FAX: (321) 724-7946 EUROPE Intersil Europe Sarl Ave. William Graisse, 3 1006 Lausanne Switzerland TEL: +41 21 6140560 FAX: +41 21 6140579 ASIA Intersil Corporation Unit 1804 18/F Guangdong Water Building 83 Austin Road TST, Kowloon Hong Kong TEL: +852 2723 6339 FAX: +852 2730 1433 HCTS164MS Spec Number 518613 Intersil Space Level Product Flow - MS Wafer Lot Acceptance, All Lots (including SEM); Method 5007 Gamma Radiation Verification, Each Wafer, 4 Samples/ Wafer, 0 Rejects, Method 1019 100% Nondestructive Bond Pull, Method 2023 Sample Wire Bond Pull Monitor, Method 2011 Sample Die Shear Monitor, Method 2019 or 2027 100% Internal Visual Inspection - Method 2010, Condition A 100% Temperature Cycling, Method 1010, Condition C, 10 Cycles 100% Constant Acceleration Method 2001, Condition per Method 5004 100% PIND, Method 2020, Condition A 100% External Visual 100% Serialization 100% Initial Electrical Test (T0) 100% Static Burn-In 1, Method 1015, Condition A or B, 24 Hours Minimum, +125oC minimum 100% Interim Electrical Test (T1) 100% Delta Calculation (T0-T1) 100% Static Burn-In 2, Method 1015, Condition A or B, 24 Hours Minimum, + 125oC Minimum 100% Interim Electrical Test 2 (T2) 100% Delta Calculation (T0-T2) 100% PDA 1, Method 5004 (see Notes 1, 2) 100% Dynamic Burn-In, Condition D, 240 Hours, +125oC or Equivalent per Method 1015 100% Interim Electrical Test 3 (T3) 100% Delta Calculation (T0-T3) 100% PDA 2, Method 5004 (see Note 2) 100% Final Electrical Test 100% Fine/Gross Leak, Method 1014 100% Radiographic, Method 2012 (see Note 3) 100% External Visual, Method 2009 Sample Group A, Method 5005 (see Note 4) 100% Data Package Generation (see Note 5) NOTES: 1. Failures from Interim Electrical Test 1 and 2 are combined for determining PDA 1. 2. Failures from subgroups 1, 7, 9 and deltas are used for calculating PDA. The maximum allowable PDA = 5% with no more than 3% of the failures from subgroup 7. 3. Radiographic (X-Ray) inspection may be performed at any point after serialization as allowed by Method 5004. 4. Alternate Group A as allowed by MIL-STD-883, Method 5005 may be performed. 5. Data package contains: • Cover Sheet (Intersil name and/or logo, PO #, customer part #, lot date code, Intersil part #, lot #, quantity). • Wafer lot acceptance report (Method 5007). Includes reproductions of SEM photos with % step coverage. GAMMA Radiation Report. Con- tains cover page, disposition, rad dose, Lot #, test package used, specifications #s, test equipment, etc. radiation read and record data on file at Intersil. • X- Ray report and film. Includes pentrameter measurements. • Screening, electrical, and group A attributes (screening attributes begin after package seal). • Lot serial number sheet (good units serial # and lot #). • Variables data (all delta operations). Data is identified by serial number. The data header includes lot # and date of test. • The Certification of Conformance is part of the shipping invoice and is not part of the data book. The Certificate of Conformance is signed by an authorized quality representative. |
Similar Part No. - HCTS164DMSR |
|
Similar Description - HCTS164DMSR |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |