Electronic Components Datasheet Search |
|
440R-A31562 Datasheet(PDF) 4 Page - Allen-Bradley |
|
440R-A31562 Datasheet(HTML) 4 Page - Allen-Bradley |
4 / 4 page Interlock Switches 3-71 Non contact Switches Ferrocode Typical Application Details Application Details Typical Configurations Typical Applications On presenting the actuator to the switch, the high-intensity electromagnetic field together with a resonant frequency signal causes the contacts to close. On removing the actuator (opening the door) the safety contacts open, isolating the machine. The switch can not be overridden by magnets, tools, etc. Safety contact operating distance: make 7mm, break 9mm Auxiliary contact operating distance: make 9mm, break 14mm On hinged doors, install switch at the opening edge. Where 2 switches are mounted adjacent, they should be no closer than 25mm. Recommend a 2mm spacing between switch and actuator. >25mm Switch Switch Actuator Actuator Actuator Spacing Actuator Approach Directions Wigan WN2 4HR 0942 55166 Actuator Made in England Ferrocode Wigan WN2 4HR 0942 55166 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Made in England Ferrocode TAMPER PROOF SAFETY SYSTEM Made in the EC FERROCODE pr EN 1088 EN 60204 pt.1 ISOLATE BEFORE REMOVING COVER ! A1 A2 X1 X2 B1 B2 S13 S14 SEE SIDE FOR SUPPLY SUPPLY Red Blue Black White Control Unit 31 32 13 14 23 24 S21S22 AUXILIARY SAFETY 1 SAFETY 2 Green Yellow POWER OUTPUT Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 TAMPER PROOF SAFETY SYSTEM Made in the EC FERROCODE pr EN 1088 EN 60204 pt.1 ISOLATE BEFORE REMOVING COVER ! SEE SIDE FOR SUPPLY SUPPLY Red Blue Black White Control Unit 31 32 13 14 23 24 S21S22 AUXILIARY SAFETY 1 SAFETY 2 Green Yellow POWER OUTPUT Wigan WN2 4HR 0942 55166 Actuator Made in England Ferrocode Wigan WN2 4HR 0942 55166 Made in England Ferrocode Safety Switch 1A 28Vdc 0.5A 120Vac IP 67 A1 A2 X1 X2 B1 B2 S13 S14 The Ferrocode switch can be used without a control unit for low risk/low power applications. Six Ferrocode switches can be used with one control unit for high risk applications. Connect the N.C. contacts (black and white wires) in series and the N.O. contacts (green and yellow wires) in parallel. One Ferrocode switch used with a control unit provides a higher integrity system. Note: Removable guards using Non contact switches may require two switches, one at either side of the guard, or the use of a flap to prevent initial lifting of the non-interlocked edge. Sliding Guard Hinged Guard Removable Guard |
Similar Part No. - 440R-A31562 |
|
Similar Description - 440R-A31562 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |