Electronic Components Datasheet Search |
|
PDM60US15 Datasheet(PDF) 1 Page - XP Power Limited |
|
PDM60US15 Datasheet(HTML) 1 Page - XP Power Limited |
1 / 2 page Specification 60 Watts • Medical & Industrial/IT Approvals • 4000 VAC Isolation • Class II Construction • Single Outputs from 12 V to 48 V • High Efficiency • Non-standard Connectors Available • Operation to +60 °C PDM60 Series Input Input Voltage • 85-264 VAC Input Frequency • 47-63 Hz Input Current • 1.5 A rms max at 85 VAC Inrush Current • 30/60 A max at 115/230 VAC cold start at +25 ºC Power Factor • Compliant with EN61000-3-2 Class A equipment Input Protection • Internal fuse in live line Output Output Voltage • See table Initial Set Accuracy • ±1% at 50% load Minimum Load • No minimum load required Start Up Delay • <500 ms Start Up Rise Time • 40 ms typical Hold Up Time • 12 ms min at 115 VAC & 100% load Drift • <±0.2% after 20 minute warm up Line Regulation • ±0.5% Load Regulation • ±3% Transient Response • 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change at 1 A/µs Ripple & Noise • 1% pk-pk, 20 MHz BW (see note 2) Overvoltage Protection • 115-150%, recycle input to reset Overload Protection • 120-170%, auto recovery Short Circuit Protection • Trip and restart (Hiccup mode) indefinite Temperature • ±0.05%/ºC Coefficient xppower.com General Efficiency • 80% typical Isolation • 4000 VAC Input to Output Switching Frequency • 55 kHz typical Power Density • 2.7 W/in3 MTBF • >420 kHrs per MIL-HDBK-217F, +40 ºC ground benign Environmental Operating Temperature • -10 ºC to +60 ºC, derate above +40 ºC by 2.5%/ºC to 50% load at +60 ºC Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -20 ºC to +85 ºC Operating Altitude • 3000 m max Shock • 30 g pk, half sine, 6 axes Vibration • 2 g, 5-500 Hz, 3 axes EMC & Safety Emissions • EN55022, level B conducted EN55022, level B radiated, EN60601-1-2, EN61204-3, FCC 20780 level B Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, 10 V/m, 80% mod Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, 10 Vrms, 80% mod Perf Criteria A Dips & Interruptions • EN61000-4-11, 70% UT 10 ms, 40% UT 100 ms, <5% UT 5000 ms Perf Criteria A, B, B Safety Approvals • EN60601-1-1, UL60601-1-1:2003, CSA60601-1, EN60950-1:2001, UL/cUL60950, CE Mark, CCC Mark |
Similar Part No. - PDM60US15 |
|
Similar Description - PDM60US15 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |