9 / 10 page
HCL Series
Miniature compensated low pressure sensors
9/10
E / 11628 / A
www.sensortechnics.com
Dual Inline Packages (DIP)
(Available for all housing styles. Sample package shown: DIP dual port, same side)
12.70
HIGH PRESSURE PORT
LOW PRESSURE PORT
4.50
9.0
10.70
4.20
2.54
0.46
5 6 7 8
4 3 2 1
3.0
Barbed pressure ports
(Available for all housing styles. Sample package shown: SMD dual port, same side)
dimensions in mm
third angle projection
Bottom view
12.70
HIGH PRESSURE PORT
LOW PRESSURE PORT
4.67
10.70
2.54
0.46
5 6 7 8
4 3 2 1
7.
00
4.0
2.50 ±0.2
5 ±0.2
dimensions in mm
third angle projection
HOUSING OPTIONS (cont.)
Different housing options are available on request. Please contact Sensortechnics.
Bottom view