  TPIC44L01DB Datasheet HTML 1Page - Texas Instruments TPIC44L01DB Datasheet HTML 2Page - Texas Instruments TPIC44L01DB Datasheet HTML 3Page - Texas Instruments TPIC44L01DB Datasheet HTML 4Page - Texas Instruments TPIC44L01DB Datasheet HTML 5Page - Texas Instruments TPIC44L01DB Datasheet HTML 6Page - Texas Instruments TPIC44L01DB Datasheet HTML 7Page - Texas Instruments TPIC44L01DB Datasheet HTML 8Page - Texas Instruments TPIC44L01DB Datasheet HTML 9Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 20 page
background image
TPIC44L01, TPIC44L02, TPIC44L03
4-CHANNEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
SLIS062A NOVEMBER 1996 – REVISED SEPTEMBER 1997
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
bit turns it off. Fault data for the device is clocked out of SDO as serial input data is clocked into the device. Fault
data consists of fault flags for shorted-load and open-load flags (bits 0–3) for each of the four output channels.
A high bit in the fault data indicates a fault and a low bit indicates that no fault is present for that channel. Fault
register bits are set or cleared asynchronously to reflect the current state of the hardware. A fault must be
present when CS is transitioned from high to low to be captured and reported in the serial fault data. New faults
cannot be captured in the serial register when CS is low. CS must be transitioned high after all of the serial data
has been clocked into the device. A low-to-high transition of CS transfers the last four bits of serial data to the
output buffer puts SDO in a high-impedence state and clears and re-enables the fault register. The
TPIC44L01/L02/L03 was designed to allow the serial input interfaces of multiple devices to be cascaded
together to simplify the serial interface to the controller. Serial input data flows through the device and is
transferred out SDO following the fault data in cascaded configurations.
For parallel operation, data is transferred directly from the parallel input interface IN0-IN3 to the respective
GATE(0–3) output asynchronously. SCLK or CS is not required for parallel control. A 1 on the parallel input turns
the respective channel on, where a 0 turns it off. Note that either the serial input interface or the parallel input
interface can enable a channel. Under parallel operation, fault data must still be collected through the serial data
interface.
The predrivers monitor the drain voltage for each channel to detect shorted-load or open-load fault conditions
in the the on and off states respectively. These devices offer the option of using an internally generated
fault-reference voltage or an externally supplied fault-reference voltage through VCOMP for fault detection. The
internal fault reference is selected by connecting VCOMPEN to GND and the external reference is selected by
connecting VCOMPEN to VCC. The drain voltage is compared to the fault reference when the channel is turned
on to detect shorted-load conditions and when the channel is off to detect open-load conditions. When a shorted
fault occurs using the TPIC44L01 or the TPIC44L03, the channel is turned off and a fault flag is sent to the control
device as well as to the serial fault register bits. If a fault occurs while using the TPIC44L02, the channel
transitions into a low-duty-cycle, pulse-width-modulated (PWM) signal as long as the fault is present.
Shorted-load fault conditions must be present for at least the shorted-load deglitch time, t(STBDG), to be flagged
as a fault. A fault flag is sent to the control device as well as the serial fault register bits. More detail on fault
detection operation is presented in the device operation section of this data sheet.
These devices provide protection from over-battery voltage and under-battery voltage conditions irrespective
of the state of the output channels. When the battery voltage is greater than the overvoltage threshold or less
than the undervoltage threshold, all channels are disabled and a fault flag is generated. Battery-voltage faults
are not reported in the serial fault data. The outputs return to normal operation once the battery-voltage fault
has been corrected. When an over-battery/under-battery voltage condition occurs, the device reports the
battery fault, but disables fault reporting for open- and shorted-load conditions. Fault reporting for open- and
shorted-load conditions are re-enabled after the battery fault condition has been corrected.
These devices provide inductive transient protection on all channels. The drain voltage is clamped to protect
the FET. The clamp voltage is defined by the sum of VC and turn-on voltage of the external FET. The predriver
also provides a gate-to-source voltage (VGS) clamp to protect the gate-source terminals of the power FET from
exceeding their rated voltages. An external active low RESET is provided to clear all registers and flags in the
device. GATE(0–3) outputs are disabled after RESET has been pulled low.
These devices provide pulldown resistors on all inputs except CS and RESET. A pullup resistor is used on CS
and RESET.


Similar Part No. - TPIC44L01DB

ManufacturerPart #DatasheetDescription
logo
Texas Instruments
TPIC44L01DB TI-TPIC44L01DB Datasheet
815Kb / 24P
[Old version datasheet]   4-CHAMMEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
TPIC44L01DBG4 TI-TPIC44L01DBG4 Datasheet
815Kb / 24P
[Old version datasheet]   4-CHAMMEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
TPIC44L01DBR TI-TPIC44L01DBR Datasheet
815Kb / 24P
[Old version datasheet]   4-CHAMMEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
TPIC44L01DBRG4 TI-TPIC44L01DBRG4 Datasheet
815Kb / 24P
[Old version datasheet]   4-CHAMMEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
More results

Similar Description - TPIC44L01DB

ManufacturerPart #DatasheetDescription
logo
STMicroelectronics
STPIC44L02 STMICROELECTRONICS-STPIC44L02 Datasheet
438Kb / 21P
   4 CHANNEL SERIAL AND PARALLEL LOW SIDE PRE-FET DRIVER
July 2003
logo
Texas Instruments
TPIC44L01DBRG4 TI-TPIC44L01DBRG4 Datasheet
815Kb / 24P
[Old version datasheet]   4-CHAMMEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
TPIC44H01 TI1-TPIC44H01_15 Datasheet
982Kb / 32P
[Old version datasheet]   4-CHANNEL SERIAL AND PARALLEL HIGH-SIDE PRE-FET DRIVER
TPIC44H01 TI-TPIC44H01 Datasheet
402Kb / 28P
[Old version datasheet]   4-CHANNEL SERIAL AND PARALLEL HIGH-SIDE PRE-FET DRIVER
TPIC46L01 TI-TPIC46L01 Datasheet
255Kb / 19P
[Old version datasheet]   6-CHANNEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
TPIC46L02DBRG4 TI1-TPIC46L02DBRG4 Datasheet
804Kb / 23P
[Old version datasheet]   6-CHANNEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER
logo
Allegro MicroSystems
A3944 ALLEGRO-A3944 Datasheet
601Kb / 31P
   Automotive, Low-Side FET Pre-Driver
A3944KLPTR-T ALLEGRO-A3944KLPTR-T Datasheet
598Kb / 31P
   Automotive, Low-Side FET Pre-Driver
logo
ELMOS Semiconductor AG
E910.32 ELMOS-E910.32 Datasheet
133Kb / 1P
   Low side driver (8 channel, parallel interface)
logo
Infineon Technologies A...
TLE7231G INFINEON-TLE7231G_15 Datasheet
906Kb / 30P
   4 channel low-side driver
Rev. 1.2, May 2014
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.NET
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com