9 / 11 page K8AB-PA 9 Checking Operation With the rated input voltage applied, gradually change the voltage to any one phase. The Unit will operate when the difference between the maximum and minimum voltage phases reaches or exceeds the asymmetry operating value. Asymmetry operating value = Rated input voltage × Asymmetry set value (%) Example: For monitoring mode set to three-phase three-wire monitoring, a rated voltage of 200 V, and an operating time of 5 s. Note: K8AB-PA @ output relays are normally operative. Connection Diagram 1 How to Measure the Operating Time Asymmetry Change the input rapidly from a symmetric state to an asymmetric state and measure the time until the relay operates. Operating Time Adjust the slide resistor so that the voltage difference applied to the K8AB terminals is equal to or greater than the asymmetry operating value when the auxiliary relay operates, as shown in connection diagram 2. Close the switch and use the cycle counter to measure the operating time. Connection Diagram 2 Checking the Phase Sequence and Phase Loss Operation Phase Sequence Operation Switch the wiring, as shown by the dotted lines in connection diagram 1, to reverse the phase sequence and check that the K8AB operates. Phase Loss Operation Create a phase loss for any input phase and check that the K8AB operates. Operating Adjustment Knobs Use a screwdriver to turn the knobs. There is a stopper to prevent the knob from turning any further once it has been turned completely to the left or right. Do not force the knob past these limits. Load-side Phase Loss In principle, phase loss cannot be detected on the load side because the K8AB-PA @ measures three-phase voltage to determine phase loss. Questions and Answers Q Alarm indicator Asymmetry operating voltage (set value) Contact T1: Startup lock time (1 s or 5 s) Flashing L1 L2 L3 T T: Operating time (0.1 to 30 s) Lit Inputs 0 to 150 V V1 Three-phase variable autotransformer L1 L2 L3 3 φ 200 VAC V2 V3 L1 L2 Q 3 φ 200 VAC L1 L2 L3 ± C 200 V Cycle counter V1 V2 V3 X X/a X/b L1 L2 L3 R1 R2 R1: Slide resistor 200 Ω 200 W R2: 100 Ω 400 W Q Q Q |
Similar Part No. - K8AB-PA1 |
|
Similar Description - K8AB-PA1 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |