2 / 26 page S8AS 2 Specifications S8AS-24006 @ Note: Refer to the next page for information on *1 to *5. Item Model S8AS-24006 S8AS-24006N S8AS-24006R Efficiency (Typ.) 80% min. Input condi- tions Voltage range *1 100 to 240 VAC (85 to 264 VAC) Frequency *1 50/60 Hz (47 to 63 Hz) Current 100-V input 3.8 A max. 200-V input 2.0 A max. Power factor 0.95 min. Harmonic current EN61000-3-2 Leakage current 100-V input 0.5 mA max. 200-V input 1.0 mA max. Inrush current *2 100-V input 25 A max. (for a cold start at 25 °C) 200-V input 50 A max. (for a cold start at 25 °C) Output condi- tions Number of branches 6 Maximum cutoff output current (per branch) 3.8 A Total output current 10 A Allowable voltage range *3 ±10% (with V.ADJ) Ripple noise voltage 2.0% [P-P] max. (for rated input and output voltage) *4 Output leakage current 10 mA max. Input fluctuation 0.5% max. (Input: 85 to 264 VAC, 100% load) *5 Load fluctuation (rated input voltage) 4.0% max. (rated input, 0% to 100% load) *5 Temperature fluctuation 0.05%/ °C max. Startup time *2 3,000 ms max. (for rated input and output voltage) *4 Output hold time *2 20 ms max. (for rated input and output voltage) *4 Func- tions Tripping functions Abnormal voltage tripping 28.8 V (Cannot be changed.) Abnormal current tripping *2 Setting range: 0.5 to 3.8 A (in 0.1-A increments) 3.8 A (Cannot be changed.) Setting range: 0.5 to 3.8 A (in 0.1-A increments) Abnormal total current tripping Branch outputs are cut off when the total output current is more than 17 A for 2 s, 15 A for 5 s, 13 A for 10 s, or 12 A for 20 s. Tripping alarm output Photoswitch output 30 VDC max. and 50 mA max., Leakage current: 0.1 mA max., Residual voltage: 2 V max. Undervoltage detection functions Undervoltage detection Setting range: 18.0 to 26.4 V (in 0.1-V increments) 20.0 V (Cannot be changed.) Setting range: 18.0 to 26.4 V (in 0.1-V increments) Undervoltage detection output Photoswitch output 30 VDC max. and 50 mA max., Leakage current: 0.1 mA max., Residual voltage: 2 V max. Maintenance forecast monitor function Maintenance forecast monitor Setting range: 0.0 to 5.0 yr (in 0.5-yr increments) 0.5 yr (Cannot be changed.) Setting range: 0.0 to 5.0 yr (in 0.5-yr increments) Maintenance forecast monitor output Photoswitch output 30 VDC max. and 50 mA max., Leakage current: 0.1 mA max., Residual voltage: 2 V max. Over- temperature detection function Over-temperature Setting range: 25 to 90 °C (in 1 °C increments) 90 °C (Cannot be changed.) Setting range: 25 to 90 °C (in 1 °C increments) Over-temperature output Photoswitch output 30 VDC max. and 50 mA max., Leakage current: 0.1 mA max., Residual voltage: 2 V max. Display functions Output voltage display Display range:17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output display range: 0.0 to 4.0 A Peak output current display range: 0.0 to 20.0 A Total current display range: 0.0 to 40.0 A Display accuracy: 5% FS (4 A) ±1 digit max. Maintenance forecast monitor display Display range: FUL (Full)/HLF (Half)/0.0 to 5.0 yr Temperature display Display range: −20 to 100°C Display accuracy: 2 °C ±1 digit max. External Tripping Input The input can be enabled or disabled for each branch output. 19.2 to 30.0 VDC, minimum signal width: 10 ms, tripping after input within 20 ms + the shutdown sequence set time All branch outputs: Enabled (Cannot be changed.) 19.2 to 30.0 VDC, minimum signal width: 10 ms, tripping after input within 20 ms + the shutdown sequence set time The input can be enabled or disabled for each branch output. 19.2 to 30.0 VDC, minimum signal width: 10 ms, tripping after input within 20 ms + the shutdown sequence set time Startup sequence Setting range: 0.0 to 99.9 s in 0.1-s increments Branch output 1: 0.0 s (Cannot be changed.) Branch output 2: 0.4 s (Cannot be changed.) Branch output 3: 0.8 s (Cannot be changed.) Branch output 4: 1.2 s (Cannot be changed.) Branch output 5: 1.6 s (Cannot be changed.) Branch output 6: 2.0 s (Cannot be changed.) Setting range: 0.0 to 99.9 s in 0.1-s increments Shutdown sequence Setting range: 0.0 to 99.9 s in 0.1-s increments All branch outputs: 0.0 s (Cannot be changed.) Setting range: 0.0 to 99.9 s in 0.1-s increments Communications Not supported Supported (RS-485) Sampling period 1 ms Parallel connection Not supported Series connection Not supported |
Similar Part No. - S8AS-24006 |
|
Similar Description - S8AS-24006 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |