Part # ACT8500-C
Description  ACT8500 Radiation Hardened & ESD Protected 64-Channel Analog Multiplexer Module
Download  10 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  AEROFLEX [Aeroflex Circuit Technology]
Direct Link  http://www.aeroflex.com
Logo AEROFLEX - Aeroflex Circuit Technology

ACT8500-C Datasheet(HTML) 3 Page - Aeroflex Circuit Technology

  ACT8500-C Datasheet HTML 1Page - Aeroflex Circuit Technology ACT8500-C Datasheet HTML 2Page - Aeroflex Circuit Technology ACT8500-C Datasheet HTML 3Page - Aeroflex Circuit Technology ACT8500-C Datasheet HTML 4Page - Aeroflex Circuit Technology ACT8500-C Datasheet HTML 5Page - Aeroflex Circuit Technology ACT8500-C Datasheet HTML 6Page - Aeroflex Circuit Technology ACT8500-C Datasheet HTML 7Page - Aeroflex Circuit Technology ACT8500-C Datasheet HTML 8Page - Aeroflex Circuit Technology ACT8500-C Datasheet HTML 9Page - Aeroflex Circuit Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 10 page
background image
Aeroflex Circuit Technology
SCD8500 REV C 10/10/01 Plainview NY (516) 694-6700
3
Organization and Application
The ACT8500 consists of six 16 channel muxes arranged as shown in the Block Diagram. The
ACT8501 design is inherently Radiation Hard due to the HS1840RH Multiplexers as well as
Microsemi Corp. Transient Suppressors (Reference Microsemi MicroNotes Series 050 - page
14).
A Section
32 channels addressable by Bus A0~A3, in two 16 channel blocks, each block enabled
separately. Each block connects the addressed channel to two outputs, "Output" and "Current".
This technique enables selecting and reading a remote resistive sensor without the MUX
resistance being part of the measurement. For grounded sensors, this is done by passing
current to the sensor by means of the "Current" pin and reading the resultant voltage
(proportional to the sensor resistance) at the "Output" pin.
B Section
32 channels addressable by Bus B0~B3, in two 16 channel blocks, each block enabled
separately. Each block connects the addressed channel to one output.
By paralleling the channel inputs and enables, this section can be converted to act like one of
the 16 channel blocks of the A section.
NOTE: It is recommended that all "NC or "no connect pin", be grounded. This eliminates or
minimizes any ESD or static buildup.


Similar Part No. - ACT8500-C

ManufacturerPart #DatasheetDescription
logo
Aeroflex Circuit Techno...
ACT8501 AEROFLEX-ACT8501 Datasheet
87Kb / 10P
   ACT8501 Radiation Hardened & ESD Protected 64-Channel Analog Multiplexer Module
ACT8501-7 AEROFLEX-ACT8501-7 Datasheet
87Kb / 10P
   ACT8501 Radiation Hardened & ESD Protected 64-Channel Analog Multiplexer Module
ACT8501-C AEROFLEX-ACT8501-C Datasheet
87Kb / 10P
   ACT8501 Radiation Hardened & ESD Protected 64-Channel Analog Multiplexer Module
ACT8501-I AEROFLEX-ACT8501-I Datasheet
87Kb / 10P
   ACT8501 Radiation Hardened & ESD Protected 64-Channel Analog Multiplexer Module
ACT8501-S AEROFLEX-ACT8501-S Datasheet
87Kb / 10P
   ACT8501 Radiation Hardened & ESD Protected 64-Channel Analog Multiplexer Module
More results

Similar Description - ACT8500-C

ManufacturerPart #DatasheetDescription
logo
Aeroflex Circuit Techno...
ACT8501 AEROFLEX-ACT8501 Datasheet
87Kb / 10P
   ACT8501 Radiation Hardened & ESD Protected 64-Channel Analog Multiplexer Module
ACT8503 AEROFLEX-ACT8503 Datasheet
84Kb / 10P
   ACT8503 Radiation Hardened & ESD Protected 48-Channel Analog Multiplexer Module
ACT8502 AEROFLEX-ACT8502 Datasheet
89Kb / 10P
   ACT8502 Radiation Hardened & ESD Protected 48-Channel Analog Multiplexer Module
ACT8510 AEROFLEX-ACT8510 Datasheet
102Kb / 8P
   ACT8510 64-Channel Analog Multiplexer Module Radiation Tolerant & ESD Protected
ACT8511 AEROFLEX-ACT8511 Datasheet
98Kb / 8P
   ACT8511 64-Channel Analog Multiplexer Module Radiation Tolerant & ESD Protected
ACT8504 AEROFLEX-ACT8504 Datasheet
92Kb / 11P
   ACT8504 Radiation Hardened & ESD Protected 64-Channel Analog Multiplexer Module With MUX Output Monitor Function
ACT8512 AEROFLEX-ACT8512 Datasheet
99Kb / 8P
   ACT8512 48-Channel Analog Multiplexer Module Radiation Tolerant & ESD Protected
MUX8530 AEROFLEX-MUX8530 Datasheet
89Kb / 8P
   MUX8530 16-Channel Analog Multiplexer Module Radiation Tolerant & ESD Protected
ACT8508 AEROFLEX-ACT8508 Datasheet
279Kb / 8P
   ACT8508 32-Channel Analog Multiplexer Module Radiation Tolerant & ESD Protected
MUX8520 AEROFLEX-MUX8520 Datasheet
89Kb / 8P
   MUX8520 16-Channel Analog Multiplexer Module Radiation Tolerant and ESD Protected
More results


Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.NET
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com