8 / 8 page EP 10. Don't exceed maximum coil voltage. Exceeding maximum allowable coil voltage on continuous basis will damage the relay and could case failure. 11. Ensure that the rated contacts voltage and current values are not exceeded. 12. The rated control capacity and life are given as guides. The contact life is heavily influenced by the type of load and other related conditions, and these factors must be kept in consideration when using the relay. 13. If you are using an inductive load (L load) such that L/R > 1 ms, add surge protection in parallel with the inductive load. If this is not done, the electrical life will decrease and cut-off failure may occur. 14. When using the 150 A type, mount it as far away as possible from Wireless transmitters or devices that may generate large surges. To prevent malfunctioning due to high emission levels, it may be neccessary to take measures for E.M.I., such as adding a line noise filter or an electromagnetic shield. 15. A slight amount of superimposed line noise may be generated in the input line the coil current control. It is recommended to install a line filter to reduce or eliminate this noise. 16. Ensure that the main terminals are clean from oils and other foreign matters. Contamination is likely to cause increase in the terminal's temperature. • 150A type: nominal cross sectional area: min. 38mm2. • 60A type: nominal cross sectional area: min. 14mm2. • 10A TM type: Faston terminal for #187 tab terminal, 0.5 mm board thickness (JIS C2809-1992 compliant, flat type connection terminal) Harness nominal cross sectional area Load input terminal: min. 1.3 mm2 Coil input terminal: min. 0.3 mm2 17. Avoid excessive stress on the terminals. Excessive stress can effect the performance of the contact operation. • M8 screw terminal (150A main terminal part) Terminal pulling up strength ; Max.100N per terminal The up-down rotation torque applied to the terminal ; Max.15N• m 18. Use 40N to 70N of force as a guide to fasten the terminal connected to the 10A TM type. Please use caution when inserting or removing the terminal as the relay tab terminal may cause injuly. 19. Place the PCB mount type (10A PCB type) securely by hand soldering after attaching it. Don't submerge assembled board in cleaning solution or water. Also, be careful not let flux overflow up from the PCB or adhere to the base of the relay. 20. Make sure the power is turned off when wiring. 21. Incorrect wiring may cause unexpected malfunction and failure. 22. For AC cut-off, there is no contact polarity. Confirm electrical life using actual load. In the case of DC cut-off, please note the contact polarity. 23. Lead-free solder (tin, silver and copper) is used as the spare solder for the terminals of the PCB mount type (10A PCB type). For Cautions for Use, see Relay Technical Information. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. |
Similar Part No. - AEP25012 |
|
Similar Description - AEP25012 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |