Electronic Components Datasheet Search |
|
TCF20 Datasheet(PDF) 1 Page - Cooper Bussmann, Inc. |
|
TCF20 Datasheet(HTML) 1 Page - Cooper Bussmann, Inc. |
1 / 2 page Low-Peak ® CUBEFuse® With and Without Indication Finger-Safe, Dual-Element, Time-Delay Class J Performance Fuse, 1-100A, 600Vac/300Vdc 0309 BU-SB09230 Page 1 of 2 Data Sheet 9000 Catalog Symbols: TCF_ Indicating fuse (6-100A) TCF_RN Non-indicating fuse (1-100A) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 100A Voltage Rating: 600Vac/300Vdc Interrupting Rating: 300kA RMS Sym. (UL) 200kA RMS Sym. (CSA) 100kA DC (UL & CSA) Agency Information: • UL Listed Special Purpose Fuse: Guide JFHR, File E56412 • CSA Certified Fuse: Class 1422- 02, File 53787 • CE compliance for the European Union low voltage directive Other Ratings/Specifications: Watts Loss at rated current: TCF30: 3.99W TCF60: 6.23W TCF100: 9.51W Operating and Storage Temperature Range: 14 to 149°F(-10 to 65°C) Material Specifications: • Case: Glass filled PES (Polyethersulfone) • Terminals: Copper alloy • Terminal plating: Electroless tin • Indicator lens: PES (Polyethersulfone) (indicating version only) • Indicator: Energetic chemical Carton Quantity and Weight Catalog Numbers (amp rating) Indicating CUBEFuse TCF6 TCF10 TCF15 TCF17-1/2 TCF20 TCF25 TCF30 TCF35 TCF40 TCF45 TCF50 TCF60 TCF70 TCF80 TCF90 TCF100 Non-Indicating CUBEFuse TCF1RN TCF3RN TCF6RN TCF10RN TCF15RN TCF17-1/2RN TCF20RN TCF25RN TCF30RN TCF35RN TCF40RN TCF45RN TCF50RN TCF60RN TCF70RN TCF80RN TCF90RN TCF100RN Features and Product Benefits • The world’s first finger-safe power fuse system. • Smallest footprint of any class fuse including Class J, CC, T and RK. • Meets Class J time-delay electrical performance requirements. • Available with and without open fuse indication to meet every customer requirement. • The indicating version features easyID™ open fuse technology for faster troubleshooting and reduced downtime. • Faster response to damaging faults to help reduce destructive thermal and magnetic forces. • True dual-element fuse construction with a minimum of 10 seconds time- delay at 500% of rating. • Long time-delay minimizes nuisance circuit openings due to temporary overloads and transient surges. • High interrupting rating to safely interrupt faults up to 300kA. • No venting of arc or molten metal and gases during opening. • Robust cycling and inrush current withstand. • Low let-through currents under fault conditions. • Provides Type 2 “No Damage” protection for IEC motors starters when properly sized. • Easy selective coordination with any other Cooper Bussmann ® Low-Peak® Class L, J and RK1 fuse with simple 2:1 amp ration between upstream and downstream fuses. Amp Carton Weight Per Carton Rating Qty. lbs kg TCF1-30A 12 1.39 0.63 TCF35-60A 12 1.42 0.65 TCF70-100A 6 1.74 0.79 CCPB 1-, 2- & 3-Pole disconnects for the Quik-Spec™ Coordination Panelboard. Data Sheet 1160 CF_ Quik-Spec™ Safety Switch disconnect (optional window). Data Sheet 1156 TCFH_N 100, 60 & 30A Holders. Data Sheet 9007 CCP_CF 1-, 2- & 3-Pole switched disconnects Data Sheet 1157 CUBEFuse Holders, Disconnects and Safety Switch The CUBEfuse is used in the following Cooper Bussmann ® products. 70-100A Case Size 35-60A Case Size 1-30A Case Size |
Similar Part No. - TCF20 |
|
Similar Description - TCF20 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |