2 / 12 page Table 1. Break Switch, SW1 and SW2 Parameters Conditions Symbol Min Typ Max Units Off-state Leakage Current: +25˚C Vsw (differential)= -320V to Gnd Isw - 0.1 1 µA Vsw (differential)= -60V to +260V +85˚C Vsw (differential)= -330V to Gnd Isw - 0.3 1 µA Vsw (differential)= -60V to +270V -40˚C Vsw (differential)= -310V to Gnd Isw - 0.1 1 µA Vsw (differential)= -60V to +250V RDS ON (SW1,SW2): +25˚C T LINE= +/-10 mA, +/-40mA, TBAT= -2V ∆ V - 14.5 - Ω +85˚C T LINE= +/-10 mA, +/-40mA, TBAT= -2V ∆ V - 20.5 28 Ω -40˚C T LINE= +/-10 mA, +/-40mA, TBAT= -2V ∆ V - 10.5 - Ω RDS ON Match Per ON-resistance Test Condition of Magnitude - 0.15 0.8 Ω SW1, SW2R ON SW1-RONSW2 dc Current Limit: +25˚C V sw (on) = +/- 10V lsw - 300 - mA +85˚C V sw (on) = +/- 10V lsw 80 160 - mA -40˚C V sw (on) = +/- 10V lsw - 400 425 mA Dynamic Current Limit: Break switches in ON state, Ringing Isw - 2.5 - A (t=<0.5µs) access switches OFF, Apply +/- 1000V at 10/1000ms pulse, Appropriate secondary protection in place. ESD Rating (HBM) 1000V Power Supply Specifications Supply Min Typ Max Unit V DD +4.5 +5.0 +5.5 V V BAT 1 -19 - -72 V www.clare.com 2 CPC7582 Rev. 1.0 Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the opera- tional sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for an extend- ed period may degrade the device and effect its reliability. Absolute Maximum Ratings (@ 25˚ C) Electrical Characteristics TA = -40oC to +85oC (unless otherwise specified) Minimum and maximum values are production testing requirements. Typical values are characteristic of the device and are the result of engineering evaluations. Typical values are provided for information purposes only and are not part of the testing requirements. 1 V BAT is used only as a reference for internal protection circuitry. If V BAT rises above -10V, the device will enter an all off state and will remain in the all off state until the battery voltage drops below -15V. Parameter Min Max Units Operating Temperature Range -40 +110 ˚C Storage Temperature Range -40 +150 ˚C Relative Humidity Range 5 95 % Pin Soldering Temperature - +260 ˚C (t=10 s max) +5V Power Supply - 7 V Battery Supply - -85 V Logic Input Voltage - 7 V Logic Input to Switch Output Isolation - 330 V Switch Isolation (SW1, SW2, SW3, SW5, SW6) - 330 V Switch Isolation (SW4) - 480 V |
Similar Part No. - CPC7582BA-TR |
|
Similar Description - CPC7582BA-TR |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |