Electronic Components Datasheet Search |
|
TMP135-36 Datasheet(PDF) 1 Page - Tumbler Technologies + TRUMPower |
|
TMP135-36 Datasheet(HTML) 1 Page - Tumbler Technologies + TRUMPower |
1 / 2 page TMP135 Series 120-135 Watts Medical & ITE Power Adapters Tumbler Technologies + TRUMPower 3350 Scott Blvd., Building 13 • Santa Clara, California 95054, USA • 408-988-6616 • sales@trumpower.com • www.TRUMPower.com TRUMPower MODELS LIST . o N t c u d o r P ) 1 ( t u p t u O e g a t l o V m u m i x a M t n e r r u C k a e P ) 2 ( t n e r r u C m u m i x a M r e w o P 2 1 - 5 3 1 P M T V 2 1A 0 . 0 1A 0 . 0 2W 0 2 1 3 1 - 5 3 1 P M T V 3 1A 3 2 . 9A 5 . 8 1W 0 2 1 5 1 - 5 3 1 P M T V 6 1 ~ 4 1A 9 2 . 9A 6 . 8 1W 0 3 1 8 1 - 5 3 1 P M T V 9 1 ~ 8 1A 0 5 . 7A 0 . 5 1W 5 3 1 0 2 - 5 3 1 P M T V 1 2 ~ 0 2A 5 7 . 6A 5 . 3 1W 5 3 1 4 2 - 5 3 1 P M T V 5 2 ~ 4 2A 3 6 . 5A 3 . 1 1W 5 3 1 8 2 - 5 3 1 P M T V 9 2 ~ 8 2A 3 8 . 4A 8 . 5W 5 3 1 0 3 - 5 3 1 P M T V 2 3 ~ 0 3A 0 5 . 4A 4 . 5W 5 3 1 6 3 - 5 3 1 P M T V 8 3 ~ 6 3A 5 7 . 3A 5 . 4W 5 3 1 8 4 - 5 3 1 P M T V 0 5 ~ 6 4A 4 9 . 2A 5 . 3W 5 3 1 INPUT SPECIFICATIONS Input Voltage Range ............ 90~264 VAC Input Frequency ................... 47~63Hz Input Current ........................ 1.60A rms @ 115 VAC 0.80A rms @ 230 VAC Inrush Current ..................... 80A @ 115 VAC or 160A @ 230 VAC, at 25°C cold start Soft Start ............................... Yes Earth Leakage Current ........ 200µA max. @ 264 VAC, 63Hz Touch Current ...................... 100µA max. @ 264 VAC, 63Hz OUTPUT SPECIFICATIONS Output Power Ratings .......... See table Minimum Load ...................... Not required Tolerance ............................. ±5% Ripple and Noise* ............... 1% peak to peak max. at full load Overvoltage Protection ........ Set at 115-140% of its nominal output voltage Overcurrent Protection ........ Protected to short-circuit conditions Temperature Coefficient ..... ±0.04%/°C max. Transient Response ........... Max. excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change * Measured with 20MHz bandwidth at rated line voltage and output load ranges, with a 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor in parallel across the output. GENERAL SPECIFICATIONS Power Factor ....................... 0.98 typical @ 115 VAC Efficiency ............................. 87% minimum at full load Hold-up Time ....................... 15ms at 110 VAC Switching Frequency ........... 90~160KHz Operating Temperature ...... 0°C to +60°C Derating ............................... Derate from 100% at +40°C linearly to 50% at +60°C Storage Temperature .......... -40°C to +85°C Relative Humidity ................ 5°C to +95°C non-condensing Withstand Voltage ............... 4000 VAC from input to output 1500 VAC from input to ground 500 VAC from output to ground MTBF .................................... 150K hours minimum at full load, 25°C ambient, calculated per MIL-HDBK-217F STANDARDS & COMPLIANCES EN 55011, EN 55022 ........ Class B, conducted & radiated FCC, VCCI ......................... Class B, conducted & radiated EN 61000-3-2 .................... Harmonic distortion, Class A & D EN 61000-3-3 .................... Line flicker EN 61000-4-2 .................... ESD, ±8 KV air and ±6 KV contact EN 61000-4-3 .................... Radiated immunity, 3V/m EN 61000-4-4 .................... Fast transient/burst, ±2 KV EN 61000-4-5 .................... Surge, ±1 KV diff., ±2 KV com. EN 61000-4-6 .................... Conducted immunity, 3 Vrms EN 61000-4-8 .................... Magnetic field immunity, 3A/m EN 61000-4-11 .................. Voltage dip immunity, 30% reduction for 500ms, 60% reduction for 100ms, >95% reduction for 10ms Safety Standards ............... UL/IEC/EN 60601-1 (3rd Edition), ANSI/AAMI ES 60601-1 (1st Edition), CSA C22.2 No. 60601-1 (2nd Edition), IEC/EN 60950-1 (2nd Edition) Agency Approvals .............. UL, cUL, TUV, CE, CB Other Compliances .......... RoHS, CEC & Energy Star Level V * Class I models certified to medical and ITE safety standards; Class II models certified to medical standard only. FEATURES • 90~264 VAC Input, Soft Start • 0.98 Active Power Factor • 87% to 91% Efficiency • High Peak Power • Low Safety Ground Leakage Current • Class I & Class II Models Available • CEC & Energy Star Level V Compliance Notes: 1) The listed P/N's are for Class I models equipped with IEC 320/C14 AC inlet. Add suffix "C2" to order Class II models equipped with IEC 320/C18 AC inlet. When ordering 14-50V output units, specify the requested voltage, e.g. use P/N TMP135-18.5-C2 to order 18.5V Class II model. 2) The peak current is for 10 seconds maximum with the average power not over the maximum power. |
Similar Part No. - TMP135-36 |
|
Similar Description - TMP135-36 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |