Electronic Components Datasheet Search |
|
MAX3098EBCSE Datasheet(PDF) 3 Page - Maxim Integrated Products |
|
MAX3098EBCSE Datasheet(HTML) 3 Page - Maxim Integrated Products |
3 / 16 page ±15kV ESD-Protected, 32Mbps, 3V/5V, Triple RS-422/RS-485 Receivers with Fault Detection _______________________________________________________________________________________ 3 ELECTRICAL CHARACTERISTICS (continued) (VCC = +3V to +5.5V, TA = TMIN to TMAX , unless otherwise noted. Typical values are at VCC = +5V and TA = +25°C.) SWITCHING CHARACTERISTICS (VCC = +3V to +5.5V, VID = ±3.0V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5V and TA = +25°C.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS VCC = 4.5V to 5.5V 75 Propagation Delay from Input to Output tPLH, tPHL CL = 15pF, Figures 1, 2 VCC = 3.0V to 3.6V 85 ns Receiver Skew |tPLH - tPHL|tSKEW CL = 15pF, Figures 1, 2 ±10 ns Channel-to-Channel Propagation Delay Skew CL = 15pF, Figures 1, 2 ±10 ns Maximum Data Rate fMAX CL = 15pF, Figure 1 32 Mbps FAULT DETECTION tDFLH 15 Differential Fault Propagation Delay to Output (Note 5) tDFHL CLF = 15pF, Figures 1, 3 1.2 µs MAX3097E (Note 6) 1.0 Minimum Differential Slew Rate to Avoid False Alarm Output MAX3098E (Note 7) 0.33 V/ µs tCMFLH 15 Common-Mode Fault Propagation Delay to Output (Note 5) tCMFHL CL = 15pF, Figures 1, 4 1.5 µs Note 1: VCM is the common-mode input voltage. VID is the differential input voltage. Note 2: VIN is the input voltage at pins A, A, B, B, Z, Z. Note 3: A differential terminating resistor is required for proper function of open-circuit fault detection (see Applications Information). Note 4: See Applications Information for a discussion of the receiver common-mode voltage range and the operating conditions for fault indication. Note 5: Applies to the individual channel immediate-fault outputs (ALARM_) and the general delayed-fault output (ALARMD) when there is no external capacitor at DELAY. Note 6: Equivalent pulse test: 1.3V / (tDFLH - tDFHL) ≥ SRD. Note 7: Equivalent pulse test: 0.62V / (tDFLH - tDFHL) ≥ SRD. PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS FDIFH High limit 70 250 MAX3098EB Fault-Detection Receiver Differential Threshold Voltage (Note 3) FDIFL VCM = 0 Low limit -250 -70 mV FCMH High limit 13.2 Fault-Detection Common-Mode Voltage Range (Note 4) FCML Low limit -10 V DELAY Current Source VCC = 5V, VDELAY = 0 9 10 11 µA VCC = 3V 1.55 1.73 1.90 DELAY Threshold VCC = 5V 3.1 3.29 3.5 V ESD PROTECTION Human Body Model ±15 IEC1000-4-2 (Air-Gap Discharge) ±15 ESD Protection (A, A, B, B, Z, Z) IEC1000-4-2 (Contact Discharge) ±8 kV |
Similar Part No. - MAX3098EBCSE |
|
Similar Description - MAX3098EBCSE |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |