11 / 13 page FM24CL16 Rev 2.2 July 2003 Page 11 of 13 Diagram Notes All start and stop timing parameters apply to both read and write cycles. Clock specifications are identical for read and write cycles. Write timing parameters apply to slave address, word address, and write data bits. Functional relationships are illustrated in the relevant data sheet sections. These diagrams illustrate the timing parameters only. Read Bus Timing t SU:SDA Start t R t F Stop Start t BUF t HIGH 1/fSCL t LOW t SP t SP Acknowledge t HD:DAT t SU:D AT t AA t DH SCL SDA Write Bus Timing t SU:STO Start Stop Start Acknowledge t AA t HD:DAT t HD:STA t SU:DAT SCL SDA Data Retention (VDD = 2.7V to 3.65V unless otherwise specified) Parameter Min Units Notes Data Retention 10 Years |
Similar Part No. - FM24CL16-S |
|
Similar Description - FM24CL16-S |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |