1 / 3 page 1 Catalog 1308242 Issued 3-03 (PDF Revised 3-09) Revised 3-09 www.tycoelectronics.com Dimensions are in inches over (millimeters) unless otherwise specified. Dimensions are shown for reference purposes only. Specifications and availability subject to change. South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080208 USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-1106-0803 Agency Approvals W54 series is UL 1077 Recognized as Supplementary Protectors, File E69543, for Canada and the United States. Available models meet Ignition Protection requirements in accordance with UL 1500 (excludes models rated >30A). CSA Accepted as Supplementary Protectors (Appliance Component Protectors), File 240027 (to 125VAC, excludes models rated >30A). Approved to VDE 0642/EN60934 (Circuit Breakers for Equipment) License Number 40007877 (excludes models rated >20A, models with screw terminals, models with silver-tin oxide contacts). CCC mark compliant, certificate 2004010307123217. Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to confirm the product meets the requirements for a given application. Time vs. Current Trip Curve @ +25°C Overload Trip Times 100% 135% 200% 300% 400% 500% 600% 800% 1000% No Trip Trip in 1 hour 5.0 - 30.0 Sec. 1.8 - 7.6 Sec. 1.0 - 4.5 Sec. 0.6 - 3.0 Sec. 0.4 - 2.2 Sec. 0.2 - 1.2 Sec. 0.15 - 0.8 Sec. .1 1 10 100 1000 Time In Seconds 1000 900 800 700 600 500 400 300 200 100 0 10,000 135 Features • 5 to 40 amp ratings. • Cannot be manually tripped. • Button extends for visual trip indication. • Push button to reset breaker. • Numerous mounting and termination options. • Choice of silver-cadmium oxide or silver-tin oxide contacts. • Optional bottom marking of amperage rating. Electrical Data @ 25°C Calibration: Will continuously carry 100% of rating. May trip between 101% and 134%, but must trip at 135% of rating within one hour at +25°C. Dielectric Strength: 1,500VAC (60 seconds). Mechanical/Environmental Data Operating Temperature Range: 0°C to +60°C. Termination: .250” (6.35mm) quick connects or #8-32 screws. Mounting: Various options. See Ordering Information and drawings. Approximate Weight: 0.9 oz. (25.0g). Current Typical Current Typical Rating Resistance Rating Resistance in Amps in Ohms in Amps in Ohms 5.0 0.050 15.0 0.017 6.0 0.042 20.0 0.012 7.0 0.036 25.0 0.010 8.0 0.031 30.0 0.008 10.0 0.025 35.0 0.007 12.0 0.021 40.0 0.006 .465 (11.8) 1.22 (31.0) .846 (21.5) SEE TERMINAL DRAWINGS FOR DETAIL 1.378 (35.0) .575 (14.6) .157 MAX. (4.0) CLOSED POSITION SEE MOUNTING BUSHING AND MOUNTING HARDWARE DRAWINGS FOR DETAIL .303 (7.7) .102 (2.6) .031 (.8) .118 DIA (3.0) Outline Dimensions Typical Resistance vs. Current Rating @25°C Insulation Resistance: 100 megohms. Maximum Operating Voltages: 50VDC; 250VAC . Interrupt Capacity: 1,000 amps in accordance with UL standard 1077. Resettable Overload Capacity: Ten times rated current. Reset Time: 60 seconds. W54 series Push To Reset Only P&B Thermal Circuit Breaker Ambient Compensation Table To use this chart: Divide the breaker rating by the correction factor to determine the compensated rating. Calculate the overloads in terms of the compensated rating to use the published trip curve. Do not use these devices outside their specified operating temperature ranges. Ambient Rating Correction Factor Temperature in °C 5-8A Models 9-30A Models 10 .90 .80 20 .98 .90 25 1.00 1.00 30 1.10 1.05 40 1.25 1.15 50 1.61 1.31 60 2.00 1.55 Optional Protective Boot Silicone rubber boot is bonded to integral alumimum nut. 1-1423696-5 Black boot for W54 with 3/8”-24 bushing. 1-1423696-6 Clear boot for W54 with M11 X 1.0 bushing. .63 DIA. (16.0) .622 (15.8) .799 (20.3) .70 DIA. (17.8) |
Similar Part No. - W54-XB1A4A10-10 |
|
Similar Description - W54-XB1A4A10-10 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |