Electronic Components Datasheet Search |
|
1659-G12-01-P10-20A Datasheet(PDF) 1 Page - ETAL Group |
|
1659-G12-01-P10-20A Datasheet(HTML) 1 Page - ETAL Group |
1 / 4 page Thermal Overcurrent Circuit Breaker 1659-... www.e-t-a.de 050215 1 1 Description Typical applications Ordering information Technical data Single pole thermal reset circuit breaker in a miniaturised design intended for thread neck mounting. Easy and quick reset after tripping due to overcurrent. Trip-free mechanism and automatic disconnection in the event of an overcurrent, even with a blocked actuator button. R-Type TO CBE to EN60934. Very cost effective design to meet international requirements. l Manual reset, trip free mechanism l Extremely small and lightweight Power tools, Industrial equipment, Medical equipment, Power generators, Motors, Battery chargers, UPS. 1659-... Standard current ratings and typical resistance Type No. 1659 single pole thermal circuit breaker, black body Threadneck design G11 M11x1,0 (Plastic), white push-to-reset button G12 M11x1,0 (Plastic), black push-to-reset button G21 3/8“-24 UNF (Plastic), white push-to-reset button G22 3/8“-24 UNF (Plastic), black push-to-reset button Hardware 00 no hardware 01 one integrated knurled nut (plastic), Y 310 777 01 for M11, Y 310 778 01 for 3/8“, bulk Terminals P10 blade terminals A6.3-0,8 (QC .250) P13 blade terminals A6.3-0,8 (QC .250), 90° S83 bent screw terminals 8-32 UNC Current ratings 5/6/7/8/10/12/15/20/25/30 A 1659-G21 -01 - P10 -5 A Ordering example Approvals Current rating (A) Typical Resistance (Ω) Current rating (A) Typical Resistance (Ω) 5 A 0.225 12 A 0.125 6 A 0.175 15 A 0.050 7 A 0.175 20 A 0.040 8 A 0.175 25 A 0.030 10 A 0.125 30 A 0.020 Voltage rating AC 250 V, DC 32 V Current ratings 5...30 A Typical life 500 operations at 1.5 x In resistive AC 125 V Behaviour at rated switching capacity (EN 60934; test sequence D) operat. IN UN 40 5...25 A AC 250 V 6 x In ind. 40 5...30 A AC 250 V 6 x In resis. 40 5...30 A DC 32 V 4 x In ind. Ambient temperatur -10 °C to +60 °C (+14...+140° F) Insulation co-ordination (IEC 60664) 2,5 kV/2 reinforced insulation in operating area Dielectric strength operating area test voltage AC 3,000 V Insulation resistance > 500 MΩ Interrupting capacity (Icn) IN UN 5...30 A AC 250 V 6 x In 5...30 A DC 32 V 6 x In Interrupting capacity (UL 1077) IN UN INC 5...30 A AC 250 V 1000 A, C, 1 5...30 A AC 250 V 400 A, U, 3 5...30 A DC 50 V 300 A, C, 1 Degree of protection (IEC 60529) operating area IP40 terminal area IP00 Vibration 57 Hz acceleration 30m/s2 (3 g) in X.Y.Z. direction (2 timesl/min.) Shock 300m/s2 (30 g) in X.Y.Z. direction Mass approx. 22 g Authority Standard Voltage rating Current ratings UL UL 1077 (E67320) AC 250 V DC 50 V 5 A...30 A 5 A...30 A TÜV SÜD EN 60934 IEC 60934 AC 250 V DC 32 V 5 A...30 A 5 A...30 A UL UL 1500 AC 250 V DC 50 V 5 A...30 A 5 A...30 A |
Similar Part No. - 1659-G12-01-P10-20A |
|
Similar Description - 1659-G12-01-P10-20A |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |