Electronic Components Datasheet Search |
|
DACT-E3 Datasheet(PDF) 2 Page - Gamewell-FCI by Honeywell |
|
DACT-E3 Datasheet(HTML) 2 Page - Gamewell-FCI by Honeywell |
2 / 4 page GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60730 Rev. G page 2 of 4 www.gamewell-fci.com Application The S3 Series Fire Alarm and Life Safety System is an easy-to-use intelligent fire alarm solution designed for the small to mid-sized buildings. Analog technology delivers the benefits of a simple system installation, while a user- friendly interface makes panel operation and system main- tenance quick and intuitive. Smart Panel Programming Using Boolean logic programming, the installer may cus- tomize the system to precisely suit the needs of the build- ing owner. Auto-programming allows the installer to instantly locate all the devices on the SLC loop. Simple, Intuitive Display The front panel display provides a user-friendly interface for the operator's control. A 4.3” (10.922 cm) color touch- screen displays system status, event details and service modes. On the front of the panel, six LEDs show the follow- ing conditions. • Fire • Silenced • Hazard (Gas or CO) • AC Power • Supervisory • Trouble Five custom programmable switches allow the user quick access to common functions specific to the building like device disable, output bypass and device status. Perfect for Retrofits The S3 Series is well-suited for retrofit applications. The SLP provides a simple way to upgrade your fire protection system. It is designed to be an upgrade solution for the leg- acy FCI 7100 and Gamewell 602 Series panels. An added feature is the SLP's EEOL. Using EEOL, the installers can automatically identify the EOL for existing audible/visual appliances. Flexibility for Future Growth The S3 Series can be expanded to add a second SLC loop without replacing the entire system. Using the RPT-E3- UTP Network Repeater, you can network up to 64 nodes (122 nodes with the ANX node expander) using either twisted-pair or fiber-optic. The built-in Ethernet port allows the connection to the Gamewell-FCI’s FocalPoint Graphical Workstation. Figure 1 LCD-SLP Display Features (Continued) • Offers an Ethernet port for programming, a variety of system reports, and a FocalPoint® Graphic Workstation connectivity. • Provides two fully-programmable Form-C contacts for Fire, Trouble, and Supervisory. • TimeCap - Saves time and date up to 48 hours without any power or battery. • Automatically adjusts to any NAC End-of-Line Resistor (EOL) value (1k-55k ohm) for legacy audible/visual appliances. • Removable display can be used as a remote annunciator. • Suitable for pre-action deluge applications. Optional Accessories DACT-E3 - Dialer The Digital Alarm Communication Transmitter sends digital signals over telephone lines to the central station. It con- nects to the SLP through an RS-485 bus. Using the Con- tact ID format, the DACT-E3 provides a four-digit account code followed by the code/numbers listed below: • Three-digit Event Code • Two-digit Group Number • Three-digit Contact Number All codes are used to provide specific point identification. The DACT-E3 is compatible with digital alarm communica- tor receivers (DACRs) that receive the following signaling formats: • Contact ID • SIA •3+1 •4+2 For more information, refer to the following data sheets: DACT-E3 Data Sheet, P/N: 9020-0610 FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 RPT-E3-UTP - Network Repeater Card The Network Repeater allows the SLP fire control panels to connect to the broadband network from remote locations. It connects to other networked units using unshielded, twisted-pair wiring. The RPT-E3-UTP is available with two add-on fiber modules: • FML-E3 connects to the network using either 62.5/125 micron multi-mode fiber. • FSL-E3 connects to the network using 9/125 micron single-mode fiber. Refer to the RPT-E3-UTP Data Sheet, P/N: 9020-0609. LCD-7100 - Remote Annunciator The Remote serial display features an 80-character dis- play. The LCD-7100 can be surface or flush-mounted on a standard 4-gang electrical box. You can use up to five LCD-7100 remote annunciators per SLP panel. For more information, refer to the LCD-7100 Data Sheet, P/N: 9020-0486. ASM-16 - Addressable Switch/LED Module There are 16 programmable switches available to perform any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g. ON, OFF, Activated, etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N: 9020-0554. ANU-48 - 48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located UL® Listed annunciator enclosure. Up to 16 ANU-48 mod- ules can be connected to the SLP panel. For more infor- mation, refer to the ANU-48 Data Sheet, P/N: 9020-0596. |
Similar Part No. - DACT-E3 |
|
Similar Description - DACT-E3 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |